Insulin ELISA kit instruction manual

Insulin ELISA kit instruction manual

This kit is for research use only.

Detection range: 96T

30pg / ml-800pg / ml

purpose of usage:

This kit is used to determine the content of Insulin in mouse serum, plasma and related liquid samples.

Experimental principle

This kit uses the double antibody sandwich method to determine the level of mouse insulin (Insulin) in the specimen. The microplate was coated with purified mouse insulin (Insulin) antibody to make a solid phase antibody. Insulin was added to the monoclonal antibody-coated microwells in turn, and then combined with HRP-labeled insulin (Insulin) antibody to form The antibody-antigen-enzyme-labeled antibody complex is thoroughly washed and added with substrate TMB for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the insulin in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of mouse insulin (Insulin) in the sample was calculated by a standard curve.

Kit composition

1

30 times concentrated washing solution

20ml × 1 bottle

7

Stop solution

6ml × 1 bottle

2

Enzyme reagent

6ml × 1 bottle

8

Standard product (1600pg / ml)

0.5ml × 1 bottle

3

Enzyme coated plate

12 holes × 8

9

Standard dilution

1.5ml × 1 bottle

4

Sample diluent

6ml × 1 bottle

10

Instructions

1 serving

5

Developer A liquid

6ml × 1 bottle

11

Sealing film

2 sheets

6

Developer B liquid

6ml × 1 / bottle

12

sealed bag

1

Specimen requirements

1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided

2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.

Steps

1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart.

800pg / ml

Standard No. 5

150μl of original standard is added to 150μl standard dilution

400pg / ml

Standard 4

150μl Standard No. 5 is added to 150μl standard dilution

200pg / ml

Standard 3

150μl Standard No. 4 is added to 150μl Standard Diluent

100pg / ml

Standard No. 2

150μl Standard No. 3 is added to 150μl Standard Diluent

50pg / ml

Standard 1

150μl Standard No. 2 is added to 150μl Standard Diluent

2. Sample addition: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the operation is the same), standard wells, sample wells to be tested. Accurately add 50μl of the standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.

3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.

4. Mixing solution: Dilute 30 times concentrated washing liquid with distilled water 30 times and reserve

5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat 5 times and pat dry.

6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.

7. Incubation: The operation is the same as 3.

8. Washing: The operation is the same as 5.

9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.

10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).

11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Summary of operating procedures:

Calculation

Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.

Precautions

1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.

2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.

3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.

4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).

5. The sealing film is limited to one-time use to avoid cross-contamination.

6. Please keep the substrate away from light.

7. Strictly follow the instructions, and the test results must be determined by the microplate reader.

8. All samples, washing liquids and various wastes should be treated as infectious agents.

9. The components of different batches of this reagent shall not be mixed.

10. If there is any difference with the English manual, the English manual shall prevail.

Storage conditions and validity period

1. Kit storage :; 2-8 ℃.

2. Validity: 6 months

Xiamen Huijia Biotechnology Co., Ltd. is a professional agent for many well-known brands in the international life science field. Committed to the sales and promotion of various ELISA kits, immunohistochemical kits, primary and secondary antibodies, cytokines, biological reagents, pipettes, and consumables.
Inquiry telephone 18906011628 http: //

Insulin ELISA kit instruction manual

Who doesn't love pizza? Now you can easily slide your pizza in and out of the oven without burning your hand. No more flimsy, plastic cutting boards, spatulas, or flexible pans that could tilt over, spilling your pizza on the floor.Our Wooden Pizza Board also serves as a sturdy Cutting Board for the pizza or for any of your favorite fruits, vegetables, or cheeses. There's no need to find a separate Serving Tray as your food can be served right on the Wood Pizza Plate.When you are done, simply rinse in your sink with warm water and soap. Lastly, you can hang this on your kitchen wall or display it on your countertop as a beautiful kitchen accessory.

Wooden Pizza Board

Wooden Pizza Board,Chopping Block,Wood Pizza Plate,Pizza Board

RealSheen Lifestyle Enterprise Limited , https://www.realsheen.com